Eaton Three Phase Freedom Starter with Heater Pack, ECN0531 with NEMA 1 Enclosure (Must make a Heater Selection at Check Out)
|
|
Item Number: ECN0531
Manufacturer: Midwest Control
Manufacturer Part No: ECN0531
Personalization
* denotes required field
Select One of the offered Heaters using Charts in Part discription, Class 10 or Class 20*
|
Eaton Three Phase Freedom Starter with Heater Pack, ECN0531 with NEMA 1 Enclosure (Must make a Heater Selection at Check Out)
Make your Desired Freedom Starter Selection from the Chart Below. You Must Select a Heater from either the Class 10 or Class 20 Selection Charts Below at Check Out.
**NO Sales Tax Guarantee (Except Illinois)** **2% Discount with a Cash/check Payment**
OEM Air Compressor Corporation supplies a full line of Air Compressor Filters/Oils/Parts & accessories for your Industrial Air Compressors. We can help you with all of your filter needs for most applications.
*Air Intake Filters * Air Compressor Filters * Air Oil Separators * Oils * Coolants Oil Filters Coalescing Filters * Water Filters * Coolant Filters * Suction Strainers Spin On Filters * Process Filters * Dust Collector Filters * EDM Filters Pleated Filters * Membrane Filters * Vacuum Filters * In Line Filters.
OEMAIR can offer a wide range of filters. We can supply filters for most machines including but not limited to compressors, trucks, forklifts, and many other applications. Call today for further details. Live Help Available! 
For Technical Support (773) 523-8200 7am - 8pm CDT
Selection Chart for Freedom NEMA Starters With Heater Packs | Adjustable Heater Pack Dial | HP | 208V | 230V | 460V | 1.0 | ECN05A1EAA | ECN05A1BAA | ECN05A1CAA | 1.5 | 2.0 | ECN0501EAA | ECN0501BAA | 3.0 | ECN0501CAA | 5.0 | ECN0511EAA | ECN0511BAA | 7.5 | ECN0511CAA | 10 | ECN0521EAA | ECN0521BAA | 15 | ECN0531EAA | ECN0521CAA | 20 | ECN0531BAA | 25 | 30 | ECN0541EAA | ECN0531CAA | 40 | | ECN0541BAA | 50 | | 60 | ECN0541CAA |
Starters Have Been Selected Based on an Average FLA Rating, These Ratings Could Be High or Low for a Specific Motor. For Fully Reliable Motor Protection it is Best to Select Your Starter Based on the Full Load Current Rating as Shown on the Motor Name Plate.
| Model Number Explanation ECN05 | A | 1 | E | A | A | Freedom NEMA Starter Non Combination Non Reversing | NEMA Contactor Size | Enclosure | Coil Voltage | Plain Cover | No Disconnect |
| | | | | |
| | | A | 110V | B | 230V | C | 460V | E | 208V | Q | 24VDC | T | 24VAC |
|
|
Trip Class 10 Heater Packs for Eaton Freedom NEMA Series | For Use With NEMA Starters Sizes 00 - 0 ( C Series ) & NEMA Sizes 1 - 2 ( B Series ) | Full Load Amp Range | Part No. | A | B | C | D | H2101B-3 | 0.26 | 0.313 | 0.367 | .420 | H2102B-3 | 0.384 | 0.464 | 0.543 | 0.623 | H2103B-3 | .570 | 0.688 | 0.806 | 0.924 | H2104B-3 | 0.846 | 1.02 | 1.20 | 1.37 | H2105B-3 | 1.28 | 1.55 | 1.83 | 2.10 | H2106B-3 | 1.92 | 2.33 | 2.74 | 3.15 | H2107B-3 | 2.3 | 2.79 | 3.28 | 3.77 | H2108B-3 | 3.38 | 4.10 | 4.82 | 5.54 | H2109B-3 | 7.07 | 6.03 | 7.09 | 8.16 | H2110B-3 | 7.07 | 8.58 | 10.1 | 11.6 | H2111B-3 | 9.60 | 11.2 | 12.8 | 14.4 | H2112B-3 | 14.4 | 17.5 | 20.7 | 23.8 | H2113B-3 | 18.7 | 21.8 | 25.0 | 28.1 | H2114B-3 | 23.5 | 27.3 | 31.0 | 34.8 | For Use With NEMA Size 2 Starters ( B Series ) | H2115B-3 | 28.3 | 32.6 | 37.0 | 41.3 | H2116B-3 | 36.6 | 42.3 | 48.1 | 53.8 | H2117B-3 | 53.8 | 60.8 | 67.9 | 74.9 |
- Columns ( A, B, C, D) Are the Dial Points (Amp Range) Listed on the Heater Pack
- Select the Appropriate Heater Pack to Meet the Motor FLA Range
- One Heater Pack Required Per Motor Starter
- Class 10 Heater Packs Are Not Available for NEMA Starters Size 3 & 4
|
|
Trip Class 20 Heater Packs for Eaton Freedom NEMA Series | For Use With NEMA Starters Sizes 00 - 0 ( C Series ) & NEMA Sizes 1 - 2 ( B Series ) | Full Load Amp Range | Part No. | A | B | C | D | H2001B-3 | 0.254 | 0.306 | 0.359 | 0.411 | H2002B-3 | 0.375 | 0.452 | 0.530 | 0.607 | H2003B-3 | 0.560 | 0.676 | 0.791 | 0.907 | H2004B-3 | 0.814 | 0.983 | 1.15 | 1.32 | H2005B-3 | 1.20 | 1.45 | 1.71 | 1.96 | H2006B-3 | 1.79 | 2.16 | 2.53 | 2.90 | H2007B-3 | 2.15 | 2.60 | 3.04 | 3.49 | H2008B-3 | 3.23 | 3.90 | 4.56 | 5.23 | H2009B-3 | 4.55 | 5.50 | 6.45 | 7.40 | H2010B-3 | 6.75 | 8.17 | 9.58 | 11.0 | H2011B-3 | 9.14 | 10.8 | 12.4 | 14.0 | H2012B-3 | 14.0 | 16.9 | 19.9 | 22.8 | H2013B-3 | 18.7 | 22.7 | 26.7 | 30.7 | H2014B-3 | 23.5 | 28.5 | 33.5 | 38.5 | For Use With NEMA Size 2 Starters ( B Series ) | H2015B-3 | 29.0 | 34.0 | 39.1 | 44.1 | H2016B-3 | 39.6 | 45.5 | 51.5 | 57.4 | H2017B-3 | 53.9 | 60.9 | 67.9 | 74.9 | For Use With NEMA Size 3 & 4 Starters ( A Series ) | H2025-3 | 8.0 | 9.2 | 10.3 | 11.5 | H2026-3 | 11.4 | 12.8 | 14.3 | 15.7 | H2027-3 | 14.3 | 15.7 | 17.4 | 19.0 | H2018-3 | 18.0 | 20.2 | 22.3 | 24.5 | H2019-3 | 24.6 | 27.6 | 30.5 | 33.4 | H2020-3 | 33.5 | 37.5 | 41.5 | 45.6 | H2021-3 | 45.7 | 51.2 | 56.7 | 62.1 | H2022-3 | 62.2 | 69.7 | 77.1 | 84.6 | H2023-3 | 84.7 | 95.0 | 105.0 | 115.0 | H2024-3 | 106.0 | 118.0 | 131.0 | 144.0 |
Columns ( A, B, C, D) Are the Dial Points (Amp Range) Listed on the Heater Pack Select the Appropriate Heater Pack to Meet the Motor FLA Range One Heater Pack Required Per Motor Starter
|
|
|
|
NO Sales Tax Guarantee! (Except Illinois)
2% Off on Cash/Check Payments (New Equipment Only)
 Live Help Available!
For Technical Support (773) 523-8200
8am - 4:30pm CDT We Donate to the Armed Forces
|
|